Generator Nitrogenii Psa Energiae Conservans Productio Professionalis Variorum Generatorum Gasis Generatorum Oxygenii Generatorum Nitrogenii Pretium

Applicatio Specifica Nitrogenii in Industria Pharmaceutica
Nitrogenium in industria pharmaceutica adhibetur, exempli gratia ad medicamenta Sinensia traditionalia nitrogenio repleta conservanda et conservanda (velut ginseng); ad injectiones medicamentorum occidentalium nitrogenio repletas; ad conservanda et recipientia nitrogenio repleta; ad fontem gasis ad medicamentorum transportationem pneumaticam, ad materias rudis pharmaceuticas protegendas, et cetera.
Characteres Technicae Generatoris Nitrogenii Medici
Series generatorum nitrogenii specialium HYN ad industriam pharmaceuticam destinatorum (plerumque cum puritate nitrogenii 99.99% vel plus) ex experientia professionali societatis nostrae in investigatione et evolutione generatorum nitrogenii adsorptionis per pressionem oscillantem per multos annos provenit. Secundum normas internationales industriae pharmaceuticae et normas GMP, partes quae cum medicamentis vel liquoribus in contactu sunt, materiam chalybis inoxidabilis adhibere debent et requisita sterilisationis observant, instrumentum ex chalybe inoxidabili factum est, et instrumentum filtrationis sterilisationis in exitu nitrogenii installatur. Quia industria pharmaceutica requisita generalia alta pro instrumentis habet, plerumque configurationes altiores adhibentur ad requisita specialia industriae implenda.
Comparatus cum nitrogenio cylindrico (vel nitrogenio liquido) in usu, sumptus operandi humiles, puritatem nitrogenii stabilem, et operationem simplicem habet.
Diagramma Fluxus
Exemplar Standard et Specificatio Generatoris Nitrogenii Medici
Modellum | Puritas | Capacitas | Consumptio aeris(m³/min) | Dimensiones (mm) L × L × A |
HYN-10 | 99 | 10 | 0.5 | 1300×1150×1600 |
99.5 | 0.59 | 1350×1170×1600 | ||
99.9 | 0.75 | 1400×1180×1670 | ||
99.99 | 1.0 | 1480×1220×1800 | ||
99.999 | 1.3 | 2000×1450×1900 | ||
HYN-20 | 99 | 20 | 0.9 | 1400×1180×1670 |
99.5 | 1.0 | 1450×1200×1700 | ||
99.9 | 1.4 | 1480×1220×1800 | ||
99.99 | 2.0 | 2050×1450×1850 | ||
99.999 | 3.0 | 2100×1500×2150 | ||
HYN-30 | 99 | 30 | 1.4 | 1400×1180×1670 |
99.5 | 1.5 | 1480×1220×1800 | ||
99.9 | 2.1 | 2050×1450×1850 | ||
99.99 | 2.8 | 2100×1500×2150 | ||
99.999 | 4.0 | 2500×1700×2450 | ||
HYN-40 | 99 | 40 | 1.8 | 1900×1400×1800 |
99.5 | 2.0 | 2000×1450×1900 | ||
99.9 | 2.8 | 2100×1500×2050 | ||
99.99 | 3.7 | 2200×1500×2350 | ||
99.999 | 6.0 | 2600×1800×2550 | ||
HYN-50 | 99 | 50 | 2.1 | 2000×1500×1900 |
99.5 | 2.5 | 2050×1450×1850 | ||
99.9 | 3.3 | 2100×1500×2250 | ||
99.99 | 4.7 | 2500×1700×2500 | ||
99.999 | 7.5 | 2700×1800×2600 | ||
HYN-60 | 99 | 60 | 2.8 | 2050×1450×1850 |
99.5 | 3.0 | 2050×1500×2100 | ||
99.9 | 4.2 | 2200×1500×2250 | ||
99.99 | 5.5 | 2550×1800×2600 | ||
99.999 | 9.0 | 2750×1850×2700 | ||
HYN-80 | 99 | 80 | 3.7 | 2100×1500×2000 |
99.5 | 4.0 | 2100×1500×2150 | ||
99.9 | 5.5 | 2500×1700×2550 | ||
99.99 | 7.5 | 2700×1800×2600 | ||
99.999 | 12.0 | 3200×2200×2800 | ||
HYN-100 | 99 | centum | 4.6 | 2100×1500×2150 |
99.5 | 5.0 | 2200×1500×2350 | ||
99.9 | 7.0 | 2650×1800×2700 | ||
99.99 | 9.3 | 2750×1850×2750 | ||
99.999 | 15.0 | 3350×2500×2800 | ||
HYN-150 | 99 | CL | 7.0 | 2150×1470×2400 |
99.5 | 7.5 | 2550×1800×2600 | ||
99.9 | 10.5 | 2750×1850×2750 | ||
99.99 | 14.0 | 3300×2500×2750 | ||
99.999 | 22.5 | 3500×3000×2900 | ||
HYN-200
| 99 | ducenti | 9.3 | 2600×1800×2550 |
99.5 | 10.0 | 2700×1800×2600 | ||
99.9 | 14.0 | 3300×2500×2800 | ||
99.99 | 18.7 | 3500×2700×2900 | ||
99.999 | 30.0 | 3600×2900×2900 |
Quomodo pretium pro Generatore Nitrogenii Medici accipiam? Ad personam aptatum accipitur.
- Fluxus N2: ______Nm3/h (quot cylindros per diem implere vis)
- Puritas N2: ________%
- Pressio exonerationis N2: ______ Bar
- Tensiones et Frequentia: ______ V/ph/Hz
- Applicatio: _______